Описание

Button:1. The backlight control.By short press the button to turn on or off the backlight, the backlight status automatic storage.2. The power cleared.Step 1: Press the button until the power area show "CLr" character, then release the button;Step 2: At this point in the power consumption flashing indicating the current status is cleared, if short press the button again, the consumption data is cleared and cleared quit flashing;
Step 3: If no key is pressed within five seconds, it means that the power does not clear the data and exit cleared.3. The voltage alarm value.Step 1: Press the button until the power area show "SET" character, then release the button;Step 2: After entering this state, the voltage of the high pressure area shows the current alarm value, the current area displays the current value of low pressure alarm, and the least significant bit starts flashing
then you can press the button through the +1 bit short, when there is no button operation When more than three seconds, the automatic adjustment of the position switch from high pressure to low pressure alarm alarm value has a value, a total of six, the scope voltage alarm threshold set for the 6.5 ~ 99.9V;Step 3: After setting, press the button until the display shows "PASS" character indicates the setting is successful and automatically exit the setting mode.
4.Range Selector.Step 1:Press the button until the power area show"Curr"character,then release the button;Step 2:At this point the current area displays"20A",short press button between "20A" and "50 A" switch, in order to represent the external current range is 20A/75mV or 50A/75mV, attention The table can only use these two specifications shunt.Step 3: Press the button until you exit the setting mode or no key operation is automatically saved after 3 seconds and exit the setting mode.
1. electrical parameter measurement function (voltage, current, power, energy).2. The voltage alarm function (over voltage alarm thresholds, backlighting and voltage flicker tips).3. The power button clear function.4. Power-down data storage function.5. Large-screen LCD screen full display function (display voltage, current, power, energy).
6. Backlight.
7. Display Interface
Display voltage, current, power, energy parameters from the large-
screen LCD screen simultaneously.
Power: measurement range 0 ~ 10kW
1kW display format within 0.0 ~ 999.9W;
From 1kW display format 1000 ~ 9999W.
Power: measurement range 0 ~ 9999kWh
10kWh within the display format 0 ~ 9999Wh;
Above 10kWh display format 10 ~ 9999kWh;
Voltage: test range 6.5 ~ 100V
Display Format 6.50 ~ 99.99V
Current: Test Range 0 ~ 20A
Display Format 0.00 to 99.99.
Working voltage: 6.5 ~ 100VDC
Test voltage: 6.5 ~ 100VDC , Accuracy: +/-1%
Rated power: 20A / 10000W
Measurement accuracy: 1.0
colour:black
Material:ABS plastic
size:2.50 * 5.00cm
Package Contents:
1x DC voltmeter
Notes:
1. This module is suitable for indoor, not outdoor use.
2. applied load can not exceed the rated voltage and current.
3. The wiring order can not be wrong.
4. This item must be used with 20A shunt.
Please choose the range of the meter to 20A before you use the 50A or 20A shunt( Factory setting20A ), this is very important.
If you choose 20A, it must be use with extra 20A shunt.
Only the above package content, other products are not included.
Note: Light shooting and different displays may cause the color of the item in the picture a little different from the real thing. The measurement allowed error is +/- 1-3cm.
Step 3: If no key is pressed within five seconds, it means that the power does not clear the data and exit cleared.3. The voltage alarm value.Step 1: Press the button until the power area show "SET" character, then release the button;Step 2: After entering this state, the voltage of the high pressure area shows the current alarm value, the current area displays the current value of low pressure alarm, and the least significant bit starts flashing
then you can press the button through the +1 bit short, when there is no button operation When more than three seconds, the automatic adjustment of the position switch from high pressure to low pressure alarm alarm value has a value, a total of six, the scope voltage alarm threshold set for the 6.5 ~ 99.9V;Step 3: After setting, press the button until the display shows "PASS" character indicates the setting is successful and automatically exit the setting mode.
4.Range Selector.Step 1:Press the button until the power area show"Curr"character,then release the button;Step 2:At this point the current area displays"20A",short press button between "20A" and "50 A" switch, in order to represent the external current range is 20A/75mV or 50A/75mV, attention The table can only use these two specifications shunt.Step 3: Press the button until you exit the setting mode or no key operation is automatically saved after 3 seconds and exit the setting mode.
1. electrical parameter measurement function (voltage, current, power, energy).2. The voltage alarm function (over voltage alarm thresholds, backlighting and voltage flicker tips).3. The power button clear function.4. Power-down data storage function.5. Large-screen LCD screen full display function (display voltage, current, power, energy).
6. Backlight.
7. Display Interface
Display voltage, current, power, energy parameters from the large-
screen LCD screen simultaneously.
Power: measurement range 0 ~ 10kW
1kW display format within 0.0 ~ 999.9W;
From 1kW display format 1000 ~ 9999W.
Power: measurement range 0 ~ 9999kWh
10kWh within the display format 0 ~ 9999Wh;
Above 10kWh display format 10 ~ 9999kWh;
Voltage: test range 6.5 ~ 100V
Display Format 6.50 ~ 99.99V
Current: Test Range 0 ~ 20A
Display Format 0.00 to 99.99.
Working voltage: 6.5 ~ 100VDC
Test voltage: 6.5 ~ 100VDC , Accuracy: +/-1%
Rated power: 20A / 10000W
Measurement accuracy: 1.0
colour:black
Material:ABS plastic
size:2.50 * 5.00cm
Package Contents:
1x DC voltmeter
Notes:
1. This module is suitable for indoor, not outdoor use.
2. applied load can not exceed the rated voltage and current.
3. The wiring order can not be wrong.
4. This item must be used with 20A shunt.
Please choose the range of the meter to 20A before you use the 50A or 20A shunt( Factory setting20A ), this is very important.
If you choose 20A, it must be use with extra 20A shunt.
Only the above package content, other products are not included.
Note: Light shooting and different displays may cause the color of the item in the picture a little different from the real thing. The measurement allowed error is +/- 1-3cm.

|

ВсеТовар мы можем отгрузить в течение 5-8 рабочих дней, обычно мыВ зависимости от времени заказа клиента для упаковки и отгрузки, мы должныВнимательно проверьте качество товара перед отправкой, поэтому ВозьмитеВремени, чтобы справиться с этим. Время доставки: Из-заК факторам форс-мажорных обстоятельств: ураганы, дождевые штормы влияют на полеты. ВедущийДля того чтобы логистика задержки. Мы честные продавцы, не дадим вам страдатьПотери. Пожалуйста, дайте логистической компании немного времени на обработку, мыПодождите, пока посылка дойдет до вашей стороны. Если ваша информация о логистике поступает в местное почтовое отделение: В том случае, еслиМестное почтовое отделение не свяжется с вами, пожалуйста, свяжитесь с вашимМестное почтовое отделение как можно скорее, чтобы получить посылка. В противном случаеСверхурочное получение посылок, местное почтовое отделение вернет вамПосылка, ответственность за себя. Время защиты заканчивается: В тех случаях, когдаМы закончили время отгрузки, если срок защиты продуктаНа исходе, пожалуйста, увеличьте срок защиты продукта самостоятельно илиСвяжитесь с нами, пожалуйста, не открывайте спор напрямую. Ввозные таможенные пошлины: НалогиИ сборы не включены в стоимость товара или стоимость доставки.Ответственность за эти расходы несет покупатель. Ввозные пошлины, налоги иРасходы не включены в стоимость товара или стоимость доставки. ЭтиРасходы оплачиваются покупателем




Если товар поврежден, мы должны связаться в течение 24 часов с момента получения.
Если данный товар находится в вашем распоряжении более 7 дней, он считается пользованным товаром, и мы не производим возврат или замену. В том случае, еслиВы не удовлетворены полученным товаром (неправильный, поврежденный,Дефект, или товар не соответствует описанию), пожалуйста, верните его в течение 7 дней дляЗамена или возврат денег.Для любогоЛичные причины (выбрать не нравится или мне не нужен этот продуктБольше), возврат расходы по доставке будет нести ответственность покупателя. МыНе принимаются какие-либо предметы с запахами (духи. Дым, и т. Д.)
ВсеВозвращенные товары должны быть в оригинальной упаковке, и вы должны предоставитьНам с номером отслеживания доставки, конкретной причиной возврата,И ваш заказ ID.Характеристики
- Бренд
- MiLESEEY
- Материалы для самостоятельного изготовления
- Электрический
- Номер модели
- DC voltmeter
- Напряжение электропитания
- 6.5 ~ 100V
- Тип дисплея
- Только цифровой
- Рабочая температура
- Other
- Класс точности
- Other
- Размеры
- 2.50 * 5.00cm